STIGQter STIGQter: STIG Summary: Tanium 7.0 Security Technical Implementation Guide Version: 1 Release: 2 Benchmark Date: 27 July 2018:

Tanium must be configured to communicate using TLS 1.2 Strict Only.

DISA Rule

SV-93537r1_rule

Vulnerability Number

V-78831

Group Title

SRG-APP-000439

Rule Version

TANS-SV-000105

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Access the Tanium SQL Server interactively.

Log on with an account with administrative privileges to the server.

Access the server's registry by typing: "regedit". Press "Enter".

Navigate to: HKEY_LOCAL_MACHINE >> SOFTWARE >> Microsoft >> .NETFramework >> v4.0.xxxxx (the sub-version number may vary, but it is a 4.0 version; example: 4.0.30319)

Right-click in the right window pane.

Select: New >> DWORD (32-bit) Value

In the "Name" field, enter "SchUseStrongCrypto" and press "Enter".

Right-click on the newly created "Name" and select "Modify..."

Leave default value of "0" in "Value data:" and ensure that under "Base" the "Hexadecimal" radio button is selected. Click "OK".

Right-click in the right window pane.

Select: New >> DWORD (32-bit) Value

In the "Name" field, enter "Enabled". Press "Enter".

Right-click on the newly created "Name" and select "Modify..."

Enter "1" in "Value data:" and ensure that under "Base" the "Hexadecimal" radio button is selected. Click "OK".

Check Contents

Access the Tanium SQL Server interactively.

Log on with an account with administrative privileges to the server.

Access the server's registry by typing: "regedit". Press "Enter".

Navigate to: HKEY_LOCAL_MACHINE >> SOFTWARE >> Microsoft >> .NETFramework >> v4.0.xxxxx (the sub-version number may vary, but it is a 4.0 version; example: 4.0.30319)

Name: SchUseStrongCrypto
Type: REG_DWORD
Data: 0x0000001 (hex)

If the value for "SchUseStrongCrypto" is not set to "0x00000001" (hex) and "Type" is not configured to "REG_DWORD" or does not exist, this is a finding.

Vulnerability Number

V-78831

Documentable

False

Rule Version

TANS-SV-000105

Severity Override Guidance

Access the Tanium SQL Server interactively.

Log on with an account with administrative privileges to the server.

Access the server's registry by typing: "regedit". Press "Enter".

Navigate to: HKEY_LOCAL_MACHINE >> SOFTWARE >> Microsoft >> .NETFramework >> v4.0.xxxxx (the sub-version number may vary, but it is a 4.0 version; example: 4.0.30319)

Name: SchUseStrongCrypto
Type: REG_DWORD
Data: 0x0000001 (hex)

If the value for "SchUseStrongCrypto" is not set to "0x00000001" (hex) and "Type" is not configured to "REG_DWORD" or does not exist, this is a finding.

Check Content Reference

M

Target Key

3215

Comments