STIGQter STIGQter: STIG Summary: HP FlexFabric Switch NDM Security Technical Implementation Guide Version: 1 Release: 3 Benchmark Date: 24 Jul 2020:

The HP FlexFabric Switch must generate audit log events for a locally developed list of auditable events.

DISA Rule

SV-80775r1_rule

Vulnerability Number

V-66285

Group Title

SRG-APP-000516-NDM-000334

Rule Version

HFFS-ND-000131

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable

Note: By default, the information center is enabled.

Check Contents

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Vulnerability Number

V-66285

Documentable

False

Rule Version

HFFS-ND-000131

Severity Override Guidance

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Check Content Reference

M

Target Key

2971

Comments