STIGQter STIGQter: STIG Summary: HP FlexFabric Switch NDM Security Technical Implementation Guide Version: 1 Release: 3 Benchmark Date: 24 Jul 2020:

The HP FlexFabric Switch must automatically audit account modification.

DISA Rule

SV-80635r1_rule

Vulnerability Number

V-66145

Group Title

SRG-APP-000027-NDM-000209

Rule Version

HFFS-ND-000010

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable

Note: By default, the information center is enabled. Account modification on the SUT generates an automatic log entry in the system's log.

Check Contents

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Vulnerability Number

V-66145

Documentable

False

Rule Version

HFFS-ND-000010

Severity Override Guidance

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Check Content Reference

M

Target Key

2971

Comments