STIGQter STIGQter: STIG Summary: Omnissa WS1 UEM Server Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 26 May 2026:

The Omnissa WS1 UEM server must be configured to record time stamps for audit records in Coordinated Universal Time (UTC).

DISA Rule

SV-284306r1224049_rule

Vulnerability Number

V-284306

Group Title

SRG-APP-000374-UEM-000244

Rule Version

OMW1-00-006600

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Authenticate to the Workspace ONE UEM console as an administrator.

Navigate to Groups & Settings >> All Settings >> System >> Enterprise Integration >> Syslog.

Next to "Syslog Format" select "RFC-5424 Format" from the drop-down menu. Click "Save".

Check Contents

Authenticate to the Workspace ONE UEM console as an administrator.

Navigate to Groups & Settings >> All Settings >> System >> Enterprise Integration >> Syslog.

If "Syslog Format" is not set to "RFC-5424 Format", this is a finding.

Vulnerability Number

V-284306

Documentable

False

Rule Version

OMW1-00-006600

Severity Override Guidance

Authenticate to the Workspace ONE UEM console as an administrator.

Navigate to Groups & Settings >> All Settings >> System >> Enterprise Integration >> Syslog.

If "Syslog Format" is not set to "RFC-5424 Format", this is a finding.

Check Content Reference

M

Target Key

5751