STIGQter STIGQter: STIG Summary: Nokia Service Router OS 25.x Network Device Management Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 28 Apr 2026:

The Nokia router must be configured to synchronize system clocks within and between systems or system components.

DISA Rule

SV-283794r1203427_rule

Vulnerability Number

V-283794

Group Title

SRG-APP-000920-NDM-000320

Rule Version

NOKI-ND-001030

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the Nokia router to synchronize system clocks within and between systems or system components.

Configure NTP server to be used for timing using the command below:

- configure system time ntp server <NTP server ip address>authentication-key <key id> key <key> type message-digest

Check Contents

Verify the Nokia router is configured to synchronize system clocks within and between systems or system components.

Verify NTP server is configured:

- show system ntp detail

NTP Status

Configured : Yes Stratum : 3
Admin Status : up Oper Status : up
Server Enabled : No Server Authenticate : No
Clock Source : 10.1.0.158
Auth Check : Yes
Auth Keychain :
Auth Errors : 0 Auth Errors Ignored : 0
Auth Key Id Errors : 0 Auth Key Type Errors : 0
Current Date & Time: 2025/12/02 13:45:31 UTC

If the Nokia router is not configured to synchronize system clocks within and between systems or system components, this is a finding.

Vulnerability Number

V-283794

Documentable

False

Rule Version

NOKI-ND-001030

Severity Override Guidance

Verify the Nokia router is configured to synchronize system clocks within and between systems or system components.

Verify NTP server is configured:

- show system ntp detail

NTP Status

Configured : Yes Stratum : 3
Admin Status : up Oper Status : up
Server Enabled : No Server Authenticate : No
Clock Source : 10.1.0.158
Auth Check : Yes
Auth Keychain :
Auth Errors : 0 Auth Errors Ignored : 0
Auth Key Id Errors : 0 Auth Key Type Errors : 0
Current Date & Time: 2025/12/02 13:45:31 UTC

If the Nokia router is not configured to synchronize system clocks within and between systems or system components, this is a finding.

Check Content Reference

M

Target Key

5744