SV-283779r1203583_rule
V-283779
SRG-APP-000375-NDM-000300
NOKI-ND-000660
CAT II
10
Configure the Nokia router to record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.
Configure the syslog for millisecond granularity using the command below:
- configure log syslog timestamp-format millisecond
Other log files use millisecond granularity by default.
Determine if the Nokia router records time stamps for audit records that meet a granularity of one second for a minimum degree of precision. This requirement may be verified by demonstration or configuration.
Verify that "TIMESTAMP Format" is set to "millisecond":
- show log log-id <log id>
show log log-id 101
498 2025/11/10 18:35:48.230 UTC MINOR: USER #2011 management admin
"User from 10.2.0.2: NFS-Sr-2s# configure log syslog 1"
If the Nokia router does not record time stamps for audit records that meet a granularity of one second for a minimum degree of precision, this is a finding.
V-283779
False
NOKI-ND-000660
Determine if the Nokia router records time stamps for audit records that meet a granularity of one second for a minimum degree of precision. This requirement may be verified by demonstration or configuration.
Verify that "TIMESTAMP Format" is set to "millisecond":
- show log log-id <log id>
show log log-id 101
498 2025/11/10 18:35:48.230 UTC MINOR: USER #2011 management admin
"User from 10.2.0.2: NFS-Sr-2s# configure log syslog 1"
If the Nokia router does not record time stamps for audit records that meet a granularity of one second for a minimum degree of precision, this is a finding.