STIGQter STIGQter: STIG Summary: HPE Alletra Storage ArcusOS Web Server Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 26 Feb 2026:

The HPE Alletra Storage ArcusOS device must be configured to collect and send SNMPv3 notifications.

DISA Rule

SV-283074r1193914_rule

Vulnerability Number

V-283074

Group Title

SRG-APP-000795-WSR-000130

Rule Version

ASMP-WS-001160

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure SNMPv3 alert notifications using the following sequence of operations:

Add the IP address of the SNMPv3 trap recipient, where permissions of the account are used:

cli% addsnmpmgr -version 3 -snmpuser Alletrasnmpuser <ip address>

Check Contents

Identify the SNMP trap recipient and report SNMP configuration:

cli% showsnmpmgr
HostIP Port SNMPVersion User Notify AlertClear
<snmp trap recipient IP> 162 3 Alletrasnmpuser standard standard

If the SNMP trap recipient IP address is incorrect, this is a finding.

If the SNMP port is not "162", this is a finding.

If the SNMP version is not "3", this is a finding.

If the SNMP user ID is incorrect, this is a finding.

Vulnerability Number

V-283074

Documentable

False

Rule Version

ASMP-WS-001160

Severity Override Guidance

Identify the SNMP trap recipient and report SNMP configuration:

cli% showsnmpmgr
HostIP Port SNMPVersion User Notify AlertClear
<snmp trap recipient IP> 162 3 Alletrasnmpuser standard standard

If the SNMP trap recipient IP address is incorrect, this is a finding.

If the SNMP port is not "162", this is a finding.

If the SNMP version is not "3", this is a finding.

If the SNMP user ID is incorrect, this is a finding.

Check Content Reference

M

Target Key

5741