SV-282695r1201065_rule
V-282695
SRG-OS-000480-GPOS-00227
TOSS-05-000223
CAT II
10
Configure TOSS 5 to not allow interfaces to perform IPv4 ICMP redirects.
Add or edit the following line in a single system configuration file, in the "/etc/sysctl.d/" directory:
net.ipv4.conf.all.send_redirects = 0
Load settings from all system configuration files using the following command:
$ sudo sysctl --system
Verify TOSS 5 does not IPv4 ICMP redirect messages using the following command:
$ sudo sysctl net.ipv4.conf.all.send_redirects
net.ipv4.conf.all.send_redirects = 0
If the returned line does not have a value of "0", or a line is not returned, this is a finding.
V-282695
False
TOSS-05-000223
Verify TOSS 5 does not IPv4 ICMP redirect messages using the following command:
$ sudo sysctl net.ipv4.conf.all.send_redirects
net.ipv4.conf.all.send_redirects = 0
If the returned line does not have a value of "0", or a line is not returned, this is a finding.
M
5738