SV-279425r1192580_rule
V-279425
SRG-APP-000359-AS-000065
NXAC-AS-000016
CAT II
10
Enable the NCC "CVM DISK | System Audit Volume Usage", set the threshold values, and verify an alert is sent when the disk capacity reaches or exceeds 75 percent.
1. Log in to Prism Element.
2. Select "Health" from the navigation drop-down.
3. Select Actions >> Manage Checks.
4. Scroll to :CVM | Disk" section, then select "System Audit Volume Usage".
5. If check is disabled, click to enable the check.
6. Select "Alert Policy", then set the values for "Warning" and "Critical" thresholds to 75 percent and click "Save".
Configure NCC within Prism Element to send an alert and emails for ISSO and SA.
1. On the Actions tab, select "Set NCC Frequency".
2. Enter frequency timeframe.
3. Enter recipient email address(es).
Confirm the NCC "CVM DISK | System Audit Volume Usage" is enabled and an alert is sent when the disk capacity reaches or exceeds 75 percent.
1. Log in to Prism Element.
2. Select "Health dashboard" from the navigation drop-down.
3. Select Actions >> Manage Checks.
4. Scroll to CVM | Disk section, and then select "System Audit Volume Usage".
5. Validate the Alert Policy settings for "Warning and Critical" are set to 75 percent.
Confirm Nutanix AOS is set to send SMTP alerts to the email address(es) for the ISSO and SA, at a minimum.
1. Log in to Prism Element.
2. Select the "Health" dashboard.
3. On the "Actions" tab, review the setting for "Set NCC Frequency".
If NCC alert settings are not configured as required, this is a finding.
V-279425
False
NXAC-AS-000016
Confirm the NCC "CVM DISK | System Audit Volume Usage" is enabled and an alert is sent when the disk capacity reaches or exceeds 75 percent.
1. Log in to Prism Element.
2. Select "Health dashboard" from the navigation drop-down.
3. Select Actions >> Manage Checks.
4. Scroll to CVM | Disk section, and then select "System Audit Volume Usage".
5. Validate the Alert Policy settings for "Warning and Critical" are set to 75 percent.
Confirm Nutanix AOS is set to send SMTP alerts to the email address(es) for the ISSO and SA, at a minimum.
1. Log in to Prism Element.
2. Select the "Health" dashboard.
3. On the "Actions" tab, review the setting for "Set NCC Frequency".
If NCC alert settings are not configured as required, this is a finding.
M