SV-279253r1170687_rule
V-279253
SRG-APP-000065-NDM-000214
SYME-ND-000500
CAT II
10
1. Log in to the Edge SWG SSH CLI.
2. Enter "enable" and "configure terminal".
3. Issue the command "security local-user-list create local".
4. Enter "security local-user-list edit local".
5. Enter "max-failed-attempts 3".
6. Enter "lockout-duration 900".
7. Enter "reset-interval 900".
1. Log in to the Edge SWG SSH CLI.
2. Enter "enable" and "configure terminal".
3. Issue the command "security local-user-list edit local", then type "view".
If "Max failed attempts" under "Account lockout" does not equal "3", this is finding.
If "Lockout duration" under "Account lockout" does not equal "900 seconds", this is a finding.
V-279253
False
SYME-ND-000500
1. Log in to the Edge SWG SSH CLI.
2. Enter "enable" and "configure terminal".
3. Issue the command "security local-user-list edit local", then type "view".
If "Max failed attempts" under "Account lockout" does not equal "3", this is finding.
If "Lockout duration" under "Account lockout" does not equal "900 seconds", this is a finding.
M
5726