SV-279080r1171402_rule
V-279080
SRG-APP-000435-AS-000163
APAS-CF-000740
CAT II
10
Configure CFTHREAD settings.
1. From the Admin Console Landing Screen, navigate to Server Settings >> Request Tuning.
2. Set Maximum number of threads available for CFTHREAD to "1" to disable unnecessary threading.
3. Click "Submit Changes".
Verify that CFTHREAD settings are appropriately configured when threading is not used by hosted applications.
1. From the Admin Console Landing Screen, navigate to Server Settings >> Request Tuning.
2. Confirm with the administrator whether any hosted applications are using CFTHREAD for multithreading.
If CFTHREAD is in use, this is not a finding.
3. If CFTHREAD is not used, verify that "Maximum number of threads available for CFTHREAD" is set to "1" to effectively disable threading.
If CFTHREAD is not used, and the "Maximum number of threads available for CFTHREAD" is set to a value other than "1", this is a finding.
V-279080
False
APAS-CF-000740
Verify that CFTHREAD settings are appropriately configured when threading is not used by hosted applications.
1. From the Admin Console Landing Screen, navigate to Server Settings >> Request Tuning.
2. Confirm with the administrator whether any hosted applications are using CFTHREAD for multithreading.
If CFTHREAD is in use, this is not a finding.
3. If CFTHREAD is not used, verify that "Maximum number of threads available for CFTHREAD" is set to "1" to effectively disable threading.
If CFTHREAD is not used, and the "Maximum number of threads available for CFTHREAD" is set to a value other than "1", this is a finding.
M
5724