STIGQter STIGQter: STIG Summary: Honeywell Android 13 COPE Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 22 Apr 2025:

Honeywell Android 13 must be configured to not allow more than 10 consecutive failed authentication attempts.

DISA Rule

SV-274381r1100713_rule

Vulnerability Number

V-274381

Group Title

PP-MDF-333040

Rule Version

HONW-13-006400

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the Honeywell Android 13 device to allow only 10 or fewer consecutive failed authentication attempts.

On the EMM console:

COBO:

1. Open "Lock screen" settings.
2. Open "Lock screen restrictions".
3. Set "Max password failures for local wipe" to a number between 1 and 10.

COPE:

1. Open "Lock screen" settings.
2. Open "Lock screen restrictions".
3. Select "Personal Profile".
4. Set "Max password failures for local wipe" to a number between 1 and 10.

Check Contents

Review managed Honeywell Android 13 device configuration settings to determine if the mobile device has the maximum number of consecutive failed authentication attempts set at 10 or fewer.

This validation procedure is performed on both the EMM Administration Console and the managed Honeywell Android 13 device.

On the EMM console:

COBO:

1. Open "Lock screen" settings.
2. Open "Lock screen restrictions".
3. Verify that "Max password failures for local wipe" is set to a number between 1 and 10.

COPE:

1. Open "Lock screen" settings.
2. Open "Lock screen restrictions".
3. Select "Personal Profile".
4. Verify that "Max password failures for local wipe" is set to a number between 1 and 10.
_________________________

On the managed Honeywell Android 13 device:

COBO and COPE:

1. Lock the device screen.
2. Attempt to unlock the screen and validate that the device autowipes after a specified number of invalid entries.
Note: Perform this verification only with a test phone set up with a production profile.

If the EMM console device policy is not set to the maximum number of consecutive failed authentication attempts at 10 or fewer, or if on the managed Honeywell Android 13 device, the device policy is not set to the maximum number of consecutive failed authentication attempts at 10 or fewer, this is a finding.

Vulnerability Number

V-274381

Documentable

False

Rule Version

HONW-13-006400

Severity Override Guidance

Review managed Honeywell Android 13 device configuration settings to determine if the mobile device has the maximum number of consecutive failed authentication attempts set at 10 or fewer.

This validation procedure is performed on both the EMM Administration Console and the managed Honeywell Android 13 device.

On the EMM console:

COBO:

1. Open "Lock screen" settings.
2. Open "Lock screen restrictions".
3. Verify that "Max password failures for local wipe" is set to a number between 1 and 10.

COPE:

1. Open "Lock screen" settings.
2. Open "Lock screen restrictions".
3. Select "Personal Profile".
4. Verify that "Max password failures for local wipe" is set to a number between 1 and 10.
_________________________

On the managed Honeywell Android 13 device:

COBO and COPE:

1. Lock the device screen.
2. Attempt to unlock the screen and validate that the device autowipes after a specified number of invalid entries.
Note: Perform this verification only with a test phone set up with a production profile.

If the EMM console device policy is not set to the maximum number of consecutive failed authentication attempts at 10 or fewer, or if on the managed Honeywell Android 13 device, the device policy is not set to the maximum number of consecutive failed authentication attempts at 10 or fewer, this is a finding.

Check Content Reference

M

Target Key