STIGQter STIGQter: STIG Summary: Honeywell Android 13 COPE Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 22 Apr 2025:

Honeywell Android 13 must be configured to lock the display after 15 minutes (or less) of inactivity.

DISA Rule

SV-274380r1100710_rule

Vulnerability Number

V-274380

Group Title

PP-MDF-333030

Rule Version

HONW-13-006300

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the Honeywell Android 13 device to enable a screen-lock policy of 15 minutes for the max period of inactivity.

Note: Honeywell Android 13 does not support the 15-minute increment. The available allowable selection is 10 minutes and then increases to 30 minutes. Therefore, the control must be set to 10 minutes.

On the EMM console:

COBO:

1. Open "Lock screen restrictions".
2. Set "Max time to screen lock" to "600".
Note: The units are in seconds.

COPE:

1. Open "Lock screen restrictions".
2. Select "Personal Profile".
3. Set "Max time to screen lock" to "600".
Note: The units are in seconds.

Check Contents

Review managed Honeywell Android device configuration settings to determine if the mobile device is enforcing a screen-lock policy that will lock the display after a period of 15 minutes or less of inactivity.

Note: Honeywell Android 13 does not support the 15-minute increment. The available allowable selection is 10 minutes and then increases to 30 minutes. Therefore, the control must be set to 10 minutes.

This validation procedure is performed on both the EMM Administration Console and the Android 13 device.

On the EMM console:

COBO:

1. Open "Lock screen restrictions".
2. Verify that "Max time to screen lock" is set to "600".
Note: The units are in seconds.

COPE:

1. Open "Lock screen restrictions".
2. Select "Personal Profile".
3. Verify that "Max time to screen lock" is set to "600".
Note: The units are in seconds.

On the managed Honeywell Android 13 device:

COBO and COPE:

1. Open Settings >> Display.
2. Tap "Screen timeout".
3. Verify that the Screen timeout value is set to "600" seconds or less.

If the EMM console device policy is not set to enable a screen-lock policy that will lock the display after a period of inactivity of 600 seconds or less, this is a finding.

Vulnerability Number

V-274380

Documentable

False

Rule Version

HONW-13-006300

Severity Override Guidance

Review managed Honeywell Android device configuration settings to determine if the mobile device is enforcing a screen-lock policy that will lock the display after a period of 15 minutes or less of inactivity.

Note: Honeywell Android 13 does not support the 15-minute increment. The available allowable selection is 10 minutes and then increases to 30 minutes. Therefore, the control must be set to 10 minutes.

This validation procedure is performed on both the EMM Administration Console and the Android 13 device.

On the EMM console:

COBO:

1. Open "Lock screen restrictions".
2. Verify that "Max time to screen lock" is set to "600".
Note: The units are in seconds.

COPE:

1. Open "Lock screen restrictions".
2. Select "Personal Profile".
3. Verify that "Max time to screen lock" is set to "600".
Note: The units are in seconds.

On the managed Honeywell Android 13 device:

COBO and COPE:

1. Open Settings >> Display.
2. Tap "Screen timeout".
3. Verify that the Screen timeout value is set to "600" seconds or less.

If the EMM console device policy is not set to enable a screen-lock policy that will lock the display after a period of inactivity of 600 seconds or less, this is a finding.

Check Content Reference

M

Target Key

5702