STIGQter STIGQter: STIG Summary: RUCKUS ICX NDM Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 27 May 2025:

The RUCKUS ICX device must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

DISA Rule

SV-273821r1111025_rule

Vulnerability Number

V-273821

Group Title

SRG-APP-000374-NDM-000299

Rule Version

RCKS-NDM-000680

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure a time zone as needed:

SSH@ICX(config) clock timezone [timezone]

Check Contents

Verify a time zone is configured on the device:

SSH@ICX# show clock
15:13:51.679 GMT+00 Mon Jan 15 2024

If the time does not reflect a time zone that can be mapped to GMT, this is a finding.

Vulnerability Number

V-273821

Documentable

False

Rule Version

RCKS-NDM-000680

Severity Override Guidance

Verify a time zone is configured on the device:

SSH@ICX# show clock
15:13:51.679 GMT+00 Mon Jan 15 2024

If the time does not reflect a time zone that can be mapped to GMT, this is a finding.

Check Content Reference

M

Target Key

5695