STIGQter STIGQter: STIG Summary: z/OS NetView for ACF2 STIG Version: 6 Release: 8 Benchmark Date: 22 Jul 2016:

NetView STC data sets are not properly protected.

DISA Rule

SV-27316r1_rule

Vulnerability Number

V-17067

Group Title

ZB000001

Rule Version

ZNETA001

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The IAO will ensure that update and allocate access to NetView STC data sets are limited to System Programmers and NetView STC only, unless a letter justifying access is filed with the IAO. Auditors should have READ access.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

Data sets to be protected will be:
SYS3.NETVIEW.<SYSTEMID>.- (VSAM data sets)

The following commands are provided as a sample for implementing dataset controls:

SET RULE
$KEY(SYS3)
NETVIEW.<systemid>.- UID(audtaudt) R(A) E(A)
NETVIEW.<systemid>.- UID(cnmproc) R(A) W(A) A(A) E(A)
NETVIEW.<systemid>.- UID(syspudt) R(A) W(A) A(A) E(A)
NETVIEW.<systemid>.- UID(tstcaudt) R(A) W(A) A(A) E(A)

The VSAM dataset required for greater than read access are:
SYS3.NETVIEW.<systemid>.AAUVSPL
SYS3.NETVIEW.<systemid>.AAUVSSL
SYS3.NETVIEW.<systemid>.BNJLGPR
SYS3.NETVIEW.<systemid>.BNJLGSE
SYS3.NETVIEW.<systemid>.BNJ36PR
SYS3.NETVIEW.<systemid>.BNJ36SE
SYS3.NETVIEW.<systemid>.DSIKPNL
SYS3.NETVIEW.<systemid>.DSILIST
SYS3.NETVIEW.<systemid>.DSILOGP
SYS3.NETVIEW.<systemid>.DSILOGS
SYS3.NETVIEW.<systemid>.DSISVRT
SYS3.NETVIEW.<systemid>.DSITRCP
SYS3.NETVIEW.<systemid>.DSITRCS
SYS3.NETVIEW.<systemid>.SDSIOPEN

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(NETVSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZNET0001)

Verify that acess to the NetView STC data sets are properly restricted.

___ The ACF2 data set rules for the data sets restricts READ access to auditors.

___ The ACF2 data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel.

___ The ACF2 data set rules for the data sets restrictS UPDATE and/or ALTER access to the product STC(s) and/or batch job(s).

Vulnerability Number

V-17067

Documentable

False

Rule Version

ZNETA001

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(NETVSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZNET0001)

Verify that acess to the NetView STC data sets are properly restricted.

___ The ACF2 data set rules for the data sets restricts READ access to auditors.

___ The ACF2 data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel.

___ The ACF2 data set rules for the data sets restrictS UPDATE and/or ALTER access to the product STC(s) and/or batch job(s).

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

1859

Comments