STIGQter STIGQter: STIG Summary: Arctic Wolf CylanceON-PREM Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 27 May 2025:

CylanceON-PREM must be running the latest release.

DISA Rule

SV-272640r1113602_rule

Vulnerability Number

V-272640

Group Title

SRG-APP-000456

Rule Version

CYLN-OP-001035

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Administrator access is required to upgrade the system.

1. Log in to the Cylance support portal (myAccount.blackberry.com) and download the latest On-Prem update package.
2. Enable Maintenance Mode.
3. Take VM Snapshots for back up purposes.
4. Navigate to CONFIGURATION >> Settings.
5. Under "CylanceON-PREM Info", select "Upgrade".
6. Choose the latest CylanceON-PREM file and click "Start Upgrade".

Monitor for the "Update is in progress" message and a "Successful update" notification upon completion. The appliance will then restart automatically.

Check Contents

Verify the system is the latest release. Administrator access is required.

Verify the version:
1. Navigate to CONFIGURATION >> Settings.
2. Verify the version.

If the system is not at the latest released version, this is a finding.

Vulnerability Number

V-272640

Documentable

False

Rule Version

CYLN-OP-001035

Severity Override Guidance

Verify the system is the latest release. Administrator access is required.

Verify the version:
1. Navigate to CONFIGURATION >> Settings.
2. Verify the version.

If the system is not at the latest released version, this is a finding.

Check Content Reference

M

Target Key

5692