STIGQter STIGQter: STIG Summary: Cloud Linux AlmaLinux OS 9 Security Technical Implementation Guide Version: 1 Release: 7 Benchmark Date: 01 Jul 2026:

AlmaLinux OS 9 must notify the system administrator (SA) and information system security officer (ISSO) (at a minimum) when allocated audit record storage volume reaches 75 percent usage.

DISA Rule

SV-269522r1050604_rule

Vulnerability Number

V-269522

Group Title

SRG-OS-000343-GPOS-00134

Rule Version

ALMA-09-053590

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure AlmaLinux OS 9 to initiate an action to notify the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of the repository maximum audit record storage capacity by adding/modifying the following line in the /etc/audit/auditd.conf file.

space_left_action = email

Check Contents

Verify AlmaLinux OS 9 notifies the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of the repository maximum audit record storage capacity with the following command:

$ grep -w space_left_action /etc/audit/auditd.conf

space_left_action = email

If the value of the "space_left_action" is not set to "email", or if the line is commented out, ask the SA to indicate how the system is providing real-time alerts to the SA and ISSO.

If there is no evidence that real-time alerts are configured on the system, this is a finding.

Vulnerability Number

V-269522

Documentable

False

Rule Version

ALMA-09-053590

Severity Override Guidance

Verify AlmaLinux OS 9 notifies the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of the repository maximum audit record storage capacity with the following command:

$ grep -w space_left_action /etc/audit/auditd.conf

space_left_action = email

If the value of the "space_left_action" is not set to "email", or if the line is commented out, ask the SA to indicate how the system is providing real-time alerts to the SA and ISSO.

If there is no evidence that real-time alerts are configured on the system, this is a finding.

Check Content Reference

M

Target Key