SV-266077r1024609_rule
V-266077
SRG-APP-000374-NDM-000299
F5BI-DM-300037
CAT II
10
From the BIG-IP GUI:
1. System.
2. Platform.
3. Set "UTC" for "Time Zone".
4. Click "Update".
From the BIG-IP Console, issue the following commands:
tmsh modify sys ntp timezone UTC
tmsh save sys config
From the BIG-IP GUI:
1. System.
2. Platform.
3. Verify that "UTC" is configured for "Time Zone".
From the BIG-IP Console, issue the following commands:
tmsh list sys ntp timezone
Note: This must return a value of "UTC".
If the BIG-IP appliance is not configured for the UTC time zone, this is a finding.
V-266077
False
F5BI-DM-300037
From the BIG-IP GUI:
1. System.
2. Platform.
3. Verify that "UTC" is configured for "Time Zone".
From the BIG-IP Console, issue the following commands:
tmsh list sys ntp timezone
Note: This must return a value of "UTC".
If the BIG-IP appliance is not configured for the UTC time zone, this is a finding.
M
5639