SV-259911r948757_rule
V-259911
SRG-VOIP-000310
SRG-VOIP-000310
CAT II
10
Implement and document that the LAN hardware supporting VVoIP services provides redundancy to support C2 assured services and FES communications.
Mandatory redundancy includes the following:
- Dual Power Supplies - Each platform must have a minimum of two power supplies, and the loss of a single power supply will not cause any loss of functions within the chassis.
- Dual Processors (Control Supervisors) - Each chassis must support dual control processors, and failure of any one processor will not cause any loss of functions within the chassis.
- Termination Sparing - Each chassis must support a (N + 1) sparing capability minimally for available Ethernet modules used to terminate to an IP subscriber.
- Protocol Redundancy - Each routing device must support protocols allowing for dynamic rerouting.
- Backplane Redundancy - Each switching platform must support a redundant (1 + 1) switching fabric or backplane, and the second fabric's backplane must be in active standby so that failure of the first does not cause loss of ongoing events within the switch. Alternately, a secondary product may be added to provide redundancy to the primary product when redundant protocols are implemented so the failover to the secondary product does not result in any lost calls.
Redundancy may not be required for VVoIP systems supporting less than 96 users, but best practice is to provide redundancy or maintain spares so service can be restored in a timely manner in the event of a failure.
If the system does not support a minimum of 96 instruments, this is not applicable.
Review site documentation to confirm the LAN hardware supporting VVoIP services provide redundancy to support C2 assured services and FES communications.
Verify the LAN hardware is redundant as follows:
- Dual Power Supplies - Each platform must have a minimum of two power supplies, and the loss of a single power supply will not cause any loss of functions within the chassis.
- Dual Processors (Control Supervisors) - Each chassis must support dual control processors, and failure of any one processor will not cause any loss of functions within the chassis.
- Termination Sparing - Each chassis must support a (N + 1) sparing capability minimally for available Ethernet modules used to terminate to an IP subscriber.
- Protocol Redundancy - Each routing device must support protocols allowing for dynamic rerouting.
- Backplane Redundancy - Each switching platform must support a redundant (1 + 1) switching fabric or backplane, and the second fabric's backplane must be in active standby so that failure of the first does not cause loss of ongoing events within the switch. Alternately, a secondary product may be added to provide redundancy to the primary product when redundant protocols are implemented so the failover to the secondary product does not result in any lost calls.
If the LAN hardware supporting VVoIP services does not provide redundancy to support C2 assured services and FES communications, this is a finding.
V-259911
False
SRG-VOIP-000310
If the system does not support a minimum of 96 instruments, this is not applicable.
Review site documentation to confirm the LAN hardware supporting VVoIP services provide redundancy to support C2 assured services and FES communications.
Verify the LAN hardware is redundant as follows:
- Dual Power Supplies - Each platform must have a minimum of two power supplies, and the loss of a single power supply will not cause any loss of functions within the chassis.
- Dual Processors (Control Supervisors) - Each chassis must support dual control processors, and failure of any one processor will not cause any loss of functions within the chassis.
- Termination Sparing - Each chassis must support a (N + 1) sparing capability minimally for available Ethernet modules used to terminate to an IP subscriber.
- Protocol Redundancy - Each routing device must support protocols allowing for dynamic rerouting.
- Backplane Redundancy - Each switching platform must support a redundant (1 + 1) switching fabric or backplane, and the second fabric's backplane must be in active standby so that failure of the first does not cause loss of ongoing events within the switch. Alternately, a secondary product may be added to provide redundancy to the primary product when redundant protocols are implemented so the failover to the secondary product does not result in any lost calls.
If the LAN hardware supporting VVoIP services does not provide redundancy to support C2 assured services and FES communications, this is a finding.