SV-259897r1173868_rule
V-259897
SRG-VOIP-000170
SRG-VOIP-000170
CAT II
10
Do one of the following:
- Architect, implement, and configure the system so the A/B, A/B/C, or A/B/C/D switch connects the CODEC to an unused switch position while it is being reconfigured during transition from one network to another.
- Architect, implement, and configure the system so the CODEC configuration is purged before it is switched to the next network, the CODEC is power cycled for the required time period as the A/B, A/B/C, or A/B/C/D switch connects the CODEC to the next network, and then the CODEC is reconfigured for that network.
- If a manual switching procedure is used, physically disconnect the CODEC from any network while it is reconfigured for the next network.
Review the VTC system architecture documentation and observe system operation while transitioning between networks to verify one of the following:
- The CODEC is switched to a disconnected/unused switch position while it is being purged/reconfigured.
- The CODEC is purged while connected to one network, power cycled as it is switched to the next network, and then reconfigured for that network.
Alternately, if a manual switching procedure is used, verify the CODEC is physically disconnected from any network while being reconfigured.
If none of these procedures is being followed, this is a finding.
V-259897
False
SRG-VOIP-000170
Review the VTC system architecture documentation and observe system operation while transitioning between networks to verify one of the following:
- The CODEC is switched to a disconnected/unused switch position while it is being purged/reconfigured.
- The CODEC is purged while connected to one network, power cycled as it is switched to the next network, and then reconfigured for that network.
Alternately, if a manual switching procedure is used, verify the CODEC is physically disconnected from any network while being reconfigured.
If none of these procedures is being followed, this is a finding.