SV-258610r997509_rule
V-258610
SRG-APP-000373-NDM-000298
IVCS-NM-000360
CAT II
10
In the ICS Web UI, navigate to System >> Status >> Overview.
1. Under "Appliance Details", and "System Date and Time", click "Edit".
2. Click "Use Pool of NTP Servers".
3. Set the IP address or hostname of the first time source.
4. In the "Key 1" box, type the number, algorithm, and key value using this format: 1 SHA1 testingkey
5. Set the IP address or hostname of the second time source, noting that this must be a time source different from the first.
6. In the "Key 2" box, type the number, algorithm, and key value using this format: 1 SHA1 testingkey.
7. Click "Save Changes".
8. Navigate to System >> Log/Monitoring >> Events >> Log on the Web UI.
9. Look in the logs for successful or unsuccessful time sync messages.
In the ICS Web UI, navigate to System >> Status >> Overview.
Under "Appliance Details", and "System Date and Time", click "Edit".
If the Time Source is not set to at least two NTP time sources, this is a finding.
If the Time Sources are not specific to a DOD authoritative time source, this is a finding.
If the Time Sources are not configured to use a SHA1 preshared key for authentication, this is a finding.
V-258610
False
IVCS-NM-000360
In the ICS Web UI, navigate to System >> Status >> Overview.
Under "Appliance Details", and "System Date and Time", click "Edit".
If the Time Source is not set to at least two NTP time sources, this is a finding.
If the Time Sources are not specific to a DOD authoritative time source, this is a finding.
If the Time Sources are not configured to use a SHA1 preshared key for authentication, this is a finding.
M
5558