SV-256707r888712_rule
V-256707
SRG-APP-000001-WSR-000001
VCLU-70-000002
CAT II
10
Navigate to and open:
/usr/lib/vmware-lookupsvc/conf/server.xml
In the <Connector> node, remove the "maxThreads" key/value pair.
Restart the service with the following command:
# vmon-cli --restart lookupsvc
At the command prompt, run the following command:
# xmllint --xpath '/Server/Service/Connector[@port="${bio-custom.http.port}"]/@maxThreads' /usr/lib/vmware-lookupsvc/conf/server.xml
Expected result:
XPath set is empty
If the output does not match the expected result, this is a finding.
V-256707
False
VCLU-70-000002
At the command prompt, run the following command:
# xmllint --xpath '/Server/Service/Connector[@port="${bio-custom.http.port}"]/@maxThreads' /usr/lib/vmware-lookupsvc/conf/server.xml
Expected result:
XPath set is empty
If the output does not match the expected result, this is a finding.
M
5525