SV-256675r888581_rule
V-256675
SRG-APP-000001-WSR-000001
VCEM-70-000003
CAT II
10
Navigate to and open:
/usr/lib/vmware-eam/web/conf/server.xml
Remove any configuration for "maxPostSize" from the <Connector> node.
Restart the service with the following command:
# vmon-cli --restart eam
At the command prompt, run the following command:
# xmllint --xpath '/Server/Service/Connector/@maxPostSize' /usr/lib/vmware-eam/web/conf/server.xml
Expected result:
XPath set is empty
If the output does not match the expected result, this is a finding.
V-256675
False
VCEM-70-000003
At the command prompt, run the following command:
# xmllint --xpath '/Server/Service/Connector/@maxPostSize' /usr/lib/vmware-eam/web/conf/server.xml
Expected result:
XPath set is empty
If the output does not match the expected result, this is a finding.
M
5524