STIGQter STIGQter: STIG Summary: IBM z/OS ACF2 Security Technical Implementation Guide Version: 9 Release: 9 Benchmark Date: 01 Jul 2026:

IBM Integrated Crypto Service Facility (ICSF) install data sets must be properly protected.

DISA Rule

SV-255933r1225876_rule

Vulnerability Number

V-255933

Group Title

SRG-OS-000080-GPOS-00048

Rule Version

ACF2-IC-000020

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Ensure that update and allocate access to IBM Integrated Crypto Service Facility (ICSF) install data sets is limited to System Programmers only, and all update and allocate access is logged. Read access can be given to Auditors and any other users that have a valid requirement to utilize these data sets.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

Data sets to be protected will be:
SYS1.CSF

The following commands are provided as a sample for implementing data set controls:

$KEY(SYS1)
CSF.- UID(syspaudt) R(A) W(L) A(L) E(A)
CSF.- UID(tstcaudt) R(A) W(L) A(L) E(A)
CSF.- UID(icsfusrs) R(A) E(A)

Check Contents

If the ESM dataset rules for the IBM Integrated Crypto Service Facility (ICSF) install data sets does not restrict UPDATE and/or ALTER access to systems programming personnel this is a finding.

If the ESM data set rules for IBM Integrated Crypto Service Facility (ICSF) install data set does not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged this is a finding.

Vulnerability Number

V-255933

Documentable

False

Rule Version

ACF2-IC-000020

Severity Override Guidance

If the ESM dataset rules for the IBM Integrated Crypto Service Facility (ICSF) install data sets does not restrict UPDATE and/or ALTER access to systems programming personnel this is a finding.

If the ESM data set rules for IBM Integrated Crypto Service Facility (ICSF) install data set does not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged this is a finding.

Check Content Reference

M

Target Key

4100