SV-254936r1067725_rule
V-254936
SRG-APP-000360
TANS-AP-000875
CAT II
10
1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multifactor authentication.
2. Click "Modules" on the top navigation banner.
3. Click "Connect".
4. Configure sources to send audit logs from the Tanium Server to a SIEM tool or email destination.
5. Work with email administrator to configure email destination.
6. Work with the SIEM administrator to configure alerts based on audit failures.
Consult documentation located at https://docs.tanium.com/connect/connect/siem.html#siem for reference on configuring other applicable SIEM connections.
1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multifactor authentication.
2. Click "Modules" on the top navigation banner.
3. Click "Connect".
4. Review the configured Tanium Sources listed.
If an "Audit Log" source does not exist, this is a finding.
5. Select the "Audit Log" source.
6. Select the audit connection found in the lower half of the screen.
7. Verify the "Destination Type" is a SIEM tool.
If the "Destination Type" is not a SIEM tool, this is a finding.
V-254936
False
TANS-AP-000875
1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multifactor authentication.
2. Click "Modules" on the top navigation banner.
3. Click "Connect".
4. Review the configured Tanium Sources listed.
If an "Audit Log" source does not exist, this is a finding.
5. Select the "Audit Log" source.
6. Select the audit connection found in the lower half of the screen.
7. Verify the "Destination Type" is a SIEM tool.
If the "Destination Type" is not a SIEM tool, this is a finding.