STIGQter STIGQter: STIG Summary: Trend Micro TippingPoint IDPS Security Technical Implementation Guide Version: 2 Release: 2 Benchmark Date: 24 Oct 2024:

The SMS must install updates on the TPS for application software files, signature definitions, detection heuristics, and vendor-provided rules when new releases are available in accordance with organizational configuration management policy and procedures.

DISA Rule

SV-242197r1018784_rule

Vulnerability Number

V-242197

Group Title

SRG-NET-000246-IDPS-00205

Rule Version

TIPP-IP-000330

Severity

CAT I

CCI(s)

Weight

10

Fix Recommendation

1. In the Trend Micro SMS, navigate to "Profiles", and "Digital Vaccines".
2. Under "Auto DV Activation", select edit.
a. Check Automatic Download.
b. Check Automatic Activation.
c. Click OK.

Check Contents

1. In the Trend Micro SMS, navigate to "Profiles", and "Digital Vaccines".
2. Under "Auto DV Activation" if "Automatic Download", and "Automatic Activation" are not enabled, this is a finding.

Vulnerability Number

V-242197

Documentable

False

Rule Version

TIPP-IP-000330

Severity Override Guidance

1. In the Trend Micro SMS, navigate to "Profiles", and "Digital Vaccines".
2. Under "Auto DV Activation" if "Automatic Download", and "Automatic Activation" are not enabled, this is a finding.

Check Content Reference

M

Target Key

5367