STIGQter STIGQter: STIG Summary: HP FlexFabric Switch NDM Security Technical Implementation Guide Version: 1 Release: 4 Benchmark Date: 02 Jul 2025:

The HP FlexFabric Switch must generate an immediate alert when allocated audit record storage volume reaches 75% of repository maximum audit record storage capacity.

DISA Rule

SV-230175r961863_rule

Vulnerability Number

V-230175

Group Title

SRG-APP-000516-NDM-000317

Rule Version

HFFS-ND-000096

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the HP FlexFabric Switch to generate an immediate alert when allocated audit record storage volume reaches 75% of repository maximum audit record storage capacity.

[HP] info-center security-logfile alarm-threshold 75

Check Contents

Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time.

[HP] display info-center

Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date

If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding.

Vulnerability Number

V-230175

Documentable

False

Rule Version

HFFS-ND-000096

Severity Override Guidance

Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time.

[HP] display info-center

Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date

If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding.

Check Content Reference

M