SV-225601r1146135_rule
V-225601
SRG-OS-000104
ZROST030
CAT II
10
The ROSCOE systems programmer and the ISSO will ensure that a product's Started Task(s) is properly identified/defined to the system ACP.
If the product requires a Started Task, verify that it is properly defined to the system ACP with the proper attributes.
Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.
A sample is provided here:
TSS CREATE(ROSCOE) TYPE(USER) -
NAME('*STC* for ROSCO') DEPT(xxxx) -
FAC(STC) -
MASTFAC(ROSCOE) PASS(xxxxxxxx,0) -
SOURCE(INTRDR) NOSUSPEND
Refer to the following report produced by the TSS Data Collection:
- TSSCMDS.RPT(@ACIDS).
Review ROSCOE STC/Batch ACID(s). If the following attributes are defined, this is not a finding.
FACILITY(STC, BATCH)
PASSWORD(xxxxxxxx,0)
SOURCE(INTRDR)
NOSUSPEND
MASTFAC(ROSCOE)
V-225601
False
ZROST030
Refer to the following report produced by the TSS Data Collection:
- TSSCMDS.RPT(@ACIDS).
Review ROSCOE STC/Batch ACID(s). If the following attributes are defined, this is not a finding.
FACILITY(STC, BATCH)
PASSWORD(xxxxxxxx,0)
SOURCE(INTRDR)
NOSUSPEND
MASTFAC(ROSCOE)
M
4206