STIGQter STIGQter: STIG Summary: z/OS ROSCOE for TSS Security Technical Implementation Guide Version: 7 Release: 2 Benchmark Date: 01 Oct 2025:

ROSCOE STC data sets are not properly protected.

DISA Rule

SV-225599r1146130_rule

Vulnerability Number

V-225599

Group Title

SRG-OS-000259

Rule Version

ZROST001

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The ISSO will ensure that WRITE and/or greater/create access to the ROSCOE started task or batch job data sets is limited to systems programmers and the started task only and all WRITE and/or greater/create access is logged.

The ISSO will ensure that all other accesses to the ROSCOE started task or batch job data sets are properly restricted and all required accesses are properly logged.

Data sets to be protected will be

SYS3.ROSCOE.SYS**
SYS3.ROSCOE.ROSLIB**

The following commands are provided as a sample for implementing data set controls:

TSS ADD(SYS3) DSN(SYS3)
TSS PER(syspaudt) DSN(SYS3.ROSCOE.SYS) ACC(R)
TSS PER(syspaudt) DSN(SYS3.ROSCOE.SYS) ACC(A) ACTION(AUDIT)
TSS PER(roscoe stc) DSN(SYS3.ROSCOE.SYS) ACC(R)
TSS PER(roscoe stc) DSN(SYS3.ROSCOE.SYS) ACC(A) ACTION(AUDIT)
TSS PER(syspaudt) DSN(SYS3.ROSCOE.ROSLIB) ACC(R)
TSS PER(syspaudt) DSN(SYS3.ROSCOE.ROSLIB) ACC(A) ACTION(AUDIT)
TSS PER(roscoe stc) DSN(SYS3.ROSCOE.ROSLIB) ACC(R)
TSS PER(roscoe stc) DSN(SYS3.ROSCOE.ROSLIB) ACC(A) ACTION(AUDIT)

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(ROSSTC).

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZROS0001).

Verify that access to the ROSCOE STC data sets are properly restricted. The data sets in this group are the data sets identified in the ROSACTxx (if used), ROSLIBxx, and SYSAWSx DD statements of the STC or batch JCL. If the following guidance is true, this is not a finding.

The TSS data set rules for the data sets restrict WRITE and/or greater access to systems programming personnel.

The TSS data set rules for the data sets restrict WRITE and/or greater access to the product STC(s) and/or batch job(s).

Vulnerability Number

V-225599

Documentable

False

Rule Version

ZROST001

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(ROSSTC).

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZROS0001).

Verify that access to the ROSCOE STC data sets are properly restricted. The data sets in this group are the data sets identified in the ROSACTxx (if used), ROSLIBxx, and SYSAWSx DD statements of the STC or batch JCL. If the following guidance is true, this is not a finding.

The TSS data set rules for the data sets restrict WRITE and/or greater access to systems programming personnel.

The TSS data set rules for the data sets restrict WRITE and/or greater access to the product STC(s) and/or batch job(s).

Check Content Reference

M

Target Key