SV-224331r1144120_rule
V-224331
SRG-OS-000104
ZNETA030
CAT II
10
The NetView systems programmer and the ISSO will ensure that a product's Started Task(s) is properly identified/defined to the System ACP.
If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.
Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.
Example:
SET LID
CHANGE NETVIEW STC MUSASS NO-SMC
Refer to the following report produced by the ACF2 Data Collection:
- ACF2CMDS.RPT(ATTSTC).
Verify that the logonid(s) for the NetView started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding.
STC
MUSASS
NO-SMC
V-224331
False
ZNETA030
Refer to the following report produced by the ACF2 Data Collection:
- ACF2CMDS.RPT(ATTSTC).
Verify that the logonid(s) for the NetView started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding.
STC
MUSASS
NO-SMC
M
4126