STIGQter STIGQter: STIG Summary: z/OS IBM Health Checker for ACF2 Security Technical Implementation Guide Version: 7 Release: 1 Benchmark Date: 02 Jul 2025:

IBM Health Checker STC data sets will be properly protected.

DISA Rule

SV-224314r1116144_rule

Vulnerability Number

V-224314

Group Title

SRG-OS-000259

Rule Version

ZHCKA001

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The ISSO will ensure that WRITE and/or greater access to IBM Health Checker STC data sets is limited to systems programmers and/or IBM Health Checker's STC(s) and/or batch user(s) only. READ access can be given to auditors.

The installing systems programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and if required that all WRITE and/or greater access is logged. The installing systems programmer will identify if any additional groups have WRITE and/or greater access for specific data sets, and once documented will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. The dataset to be protected can be found in the HZSPROC STC member in HZSPDATA DD statement.

Data sets to be protected will be:
SYS3.*.HZSPDATA

The following commands are provided as a sample for implementing data set controls:

$KEY(S3A)
$PREFIX(SYS3)
MVA.HZSPDATA UID(syspaudt) R(A) W(A) A(A) E(A)
MVA.HZSPDATA UID(Health Checker STCs) R(A) W(A) A(A) E(A)
MVA.HZSPDATA UID(audtaudt) R(A) E(A)

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(HCKSTC)

Automated Analysis:
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZHCK0001)

Verify that the accesses to the IBM Health Checker STC data sets are properly restricted. If the following guidance is true, this is not a finding:

The ACF2 data set rules for the data sets restricts READ access to auditors.

The ACF2 data set rules for the data sets restricts WRITE and/or greater access to systems programming personnel.

The ACF2 data set rules for the data sets restricts WRITE and/or greater access to the IBM Health Checker's STC(s) and/or batch user(s).

Vulnerability Number

V-224314

Documentable

False

Rule Version

ZHCKA001

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(HCKSTC)

Automated Analysis:
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZHCK0001)

Verify that the accesses to the IBM Health Checker STC data sets are properly restricted. If the following guidance is true, this is not a finding:

The ACF2 data set rules for the data sets restricts READ access to auditors.

The ACF2 data set rules for the data sets restricts WRITE and/or greater access to systems programming personnel.

The ACF2 data set rules for the data sets restricts WRITE and/or greater access to the IBM Health Checker's STC(s) and/or batch user(s).

Check Content Reference

M

Target Key

4123