STIGQter STIGQter: STIG Summary: z/OS BMC CONTROL-M/Restart for ACF2 Security Technical Implementation Guide Version: 7 Release: 2 Benchmark Date: 01 Oct 2025:

BMC CONTROL-M/Restart Archived Sysout datasets must be properly protected.

DISA Rule

SV-224122r1141494_rule

Vulnerability Number

V-224122

Group Title

SRG-OS-000080

Rule Version

ZCTRA002

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Ensure that WRITE and/or greater access to BMC CONTROL-M/Restart Archived Sysout datasets is limited to production control scheduling personnel, scheduled batch users, systems programmers, and the BMC STCs and/or batch users only. READ access can be given to auditors and BMC users.

The installing systems programmer will identify and document the product datasets, categorize them according to who will have WRITE and/or greater access, and if required, ensure that all WRITE and/or greater access is logged.

The installing systems programmer will identify if any additional groups have WRITE and/or greater access for specific datasets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system.

(Note: The datasets and/or dataset prefixes identified below are examples of a possible installation. The actual datasets and/or prefixes are determined when the product is installed on a system through the product's installation guide and can be site specific.)

Datasets to be protected will be:
CTRSYS

The following commands are provided as a sample for implementing dataset controls:

$KEY(CTRSYS)
- UID(<syspaudt>) R(A) W(A) A(A) E(A)
- UID(CONTROLM) R(A) W(A) A(A) E(A)
- UID(CONTDAY) R(A) W(A) A(A) E(A)
- UID(<audtaudt>) R(A) E(A)
- UID(<bmcuser>) R(A) E(A)
- UID(<autoaudt>) R(A) W(A) A(A) E(A)
- UID(<pcspaudt>) R(A) W(A) A(A) E(A)

Check Contents

Refer to the following report produced by the dataset and Resource Data Collection:

- SENSITVE.RPT(CTRUSER).

Automated Analysis
Refer to the following report produced by the dataset and Resource Data Collection:

- PDI(ZCTR0002).

Verify that the accesses to the BMC CONTROL-M/Restart Archived Sysout datasets are properly restricted. If the following guidance is true, this is not a finding.

The ACF2 dataset access authorizations restrict READ access to auditors and BMC Users.

The ACF2 dataset access authorizations restrict WRITE and/or greater access to production control and scheduling personnel, scheduled batch user(s), systems programming personnel, and the BMC STCs and/or batch users.

Vulnerability Number

V-224122

Documentable

False

Rule Version

ZCTRA002

Severity Override Guidance

Refer to the following report produced by the dataset and Resource Data Collection:

- SENSITVE.RPT(CTRUSER).

Automated Analysis
Refer to the following report produced by the dataset and Resource Data Collection:

- PDI(ZCTR0002).

Verify that the accesses to the BMC CONTROL-M/Restart Archived Sysout datasets are properly restricted. If the following guidance is true, this is not a finding.

The ACF2 dataset access authorizations restrict READ access to auditors and BMC Users.

The ACF2 dataset access authorizations restrict WRITE and/or greater access to production control and scheduling personnel, scheduled batch user(s), systems programming personnel, and the BMC STCs and/or batch users.

Check Content Reference

M

Target Key

4105