SV-220689r1188389_rule
V-220689
SRG-NET-000512-L2S-000004
CISC-L2-000190
CAT II
10
Configure the switch to enable Unidirectional Link Detection (UDLD) to protect against one-way connections.
SW1(config)# feature udld
If any of the switch ports have fiber optic interconnections with neighbors, review the switch configuration to verify that either UDLD is enabled globally or not explicitly disabled on a per interface basis as shown in the examples below.
hostname SW1
…
…
…
feature udld
or
interface GigabitEthernet0/3
udld disabled
Note: By default, UDLD is enabled on all interfaces with fiber optic connections. An alternative implementationwhen UDLD is not supported by connected device is to deploy a single member Link Aggregation Group (LAG) via IEEE 802.3ad Link Aggregation Control Protocol (LACP).
If the switch has fiber optic interconnections with neighbors and UDLD is not enabled, this is a finding.
V-220689
False
CISC-L2-000190
If any of the switch ports have fiber optic interconnections with neighbors, review the switch configuration to verify that either UDLD is enabled globally or not explicitly disabled on a per interface basis as shown in the examples below.
hostname SW1
…
…
…
feature udld
or
interface GigabitEthernet0/3
udld disabled
Note: By default, UDLD is enabled on all interfaces with fiber optic connections. An alternative implementationwhen UDLD is not supported by connected device is to deploy a single member Link Aggregation Group (LAG) via IEEE 802.3ad Link Aggregation Control Protocol (LACP).
If the switch has fiber optic interconnections with neighbors and UDLD is not enabled, this is a finding.
M
4073