STIGQter STIGQter: STIG Summary: Mainframe Product Security Requirements Guide Version: 3 Release: 5 Benchmark Date: 01 Jul 2026:

The Mainframe Product must either shut down, restart, and/or notify the appropriate personnel when anomalies in the operation of the security functions as defined in site security plan are discovered.

DISA Rule

SV-205593r961737_rule

Vulnerability Number

V-205593

Group Title

SRG-APP-000474

Rule Version

SRG-APP-000474-MFP-000373

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the Mainframe Product to shut down; and/or restart and notify system programmer and operation staff when anomalies in the operation of the security functions as defined in site security plan are discovered.

Check Contents

Examine installation and configuration setting

If the Mainframe Product is not configured to shut down; and/or restart and notify system programmer and operation staff when anomalies in the operation of security functions as defined by site security plan are discovered, this is a finding.

Vulnerability Number

V-205593

Documentable

False

Rule Version

SRG-APP-000474-MFP-000373

Severity Override Guidance

Examine installation and configuration setting

If the Mainframe Product is not configured to shut down; and/or restart and notify system programmer and operation staff when anomalies in the operation of security functions as defined by site security plan are discovered, this is a finding.

Check Content Reference

M

Target Key

2906